Thank you for visiting!
Our website is being updated.

APC Smart-UPS 2200VA USB & Serial RM 2U 230V

APC Smart-UPS 2200VA USB & Serial RM 2U 230V

Includes: CD with software, Rack Mounting brackets, Smart UPS signalling RS-232 cable, USB cable, User Manual

 

 

 

Output
Output Power Capacity 1980 Watts / 2200 VA
Max Configurable Power 1980 Watts / 2200 VA
Nominal Output Voltage 230V
Output Voltage Distortion Less than 5% full load
Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage
Output Frequency (sync to mains) 47 – 53 Hz for 50 Hz nominal, 57 – 63 Hz for 60 Hz nominal
Topology Line Interactive
Waveform Type Sine wave
Output Connections
(8) IEC 320 C13(1) IEC 320 C19

(2) IEC Jumpers

Input
Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections Hard Wire 3-wire
Input voltage range for main operations
IEC-320 C20
Schuko CEE 7 / EU1-16P
British BS1363A
Input voltage range for main operations 160 – 286V
Input voltage adjustable range for mains operation 151 – 302V
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time 3 hour(s)
Replacement Battery RBC43
Communications & Management
Interface Port(s) DB-9 RS-232, SmartSlot ,USB
Available SmartSlot™ Interface Quantity 1
Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays
Control panel LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : and Overload Indicators
Emergency Power Off (EPO) Yes

продвижение сайтаindependent escorts ukфункциональный тренинг кузьминки

Overview


11B

Features


Feature and benefits

Availability
Boost and Trim Automatic Voltage Regulation (AVR Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging chargingProlongs battery life by regulating the charge voltage according to battery temperature.

 

Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification Warns when a battery is not available to provide backup power.
Manageability
Network manageable Provides remote power management of the UPS over the network.
Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition
LED status indicators Quickly understand unit and power status with visual indicators
Serial connectivity Provides management of the UPS via a serial port.
USB connectivity Provides management of the UPS via a USB port (not available on all models)
Disconnected battery notification Warns when a battery is not available to provide backup power.
Serviceability
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement. 
Resettable circuit breakers Enables a quick recovery from overload events. 
Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Adaptability
Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications
Safety
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Benefits


Default backup time


Customer Support: (08) 38.420.458

Head Office

219 Nguyen Dinh Chinh, Ward 11,
Phu Nhuan Dist, Ho Chi Minh City, Vietnam.
Tel: (+84)8.38.420.458 - Fax: (+84).8.38.420.459
Hotline: 0938.805.380 (Mr.Tuấn)

Representative Office

Room 402, 85 Nguyen Chi Thanh,
Dong Da Dist, Hanoi, Vietnam
Tel: (+84)4.35.668.011 - Fax: (+84)4.35.668.030