APC Smart-UPS RT 2000VA 230V

APC Smart-UPS RT 2000VA 230V

Includes: CD with software, Smart UPS signalling RS-232 cable, User Manual,

Output
Output Power Capacity 1400 Watts / 2000 VA
Max Configurable Power 1400 Watts / 2000 VA
Nominal Output Voltage 230V
Efficiency at Full Load 91.0%
Output Voltage Distortion Less than 3% full load
Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage
Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Topology Double Conversion Online
Other Output Voltages 220, 240
Crest Factor 3 : 1
Waveform Type Sine wave
Output Connections
(8) IEC 320 C13(4) IEC Jumpers
Bypass Built-in Bypass
Input
Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 5 Hz (auto sensing)
Input Connections
British BS1363AIEC-320 C20Schuko CEE 7/EU1-16P
Input voltage range for main operations 160 – 280V
Input voltage adjustable range for mains operation 100 – 280V
Other Input Voltages 220, 240
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules 2
Typical recharge time 4 hour(s)
Replacement Battery RBC31
RBC™ Quantity 1
Communications & Management
Interface Port(s) DB-9 RS-232, SmartSlot
Available SmartSlot™ Interface Quantity 1
Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays
Control panel LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators
Emergency Power Off (EPO) Optional

комплексная поисковая оптимизацияhot girls massageбокс индивидуальные тренировки

Overview


2000

Features


Smart-UPS On-Line Features & Benefits

Availability
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtime Allows additional run time to be quickly added as needed.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Manageability
Network manageable Provides remote power management of the UPS over the network.
SmartSlot Enables centralized management via the APC InfraStruXure Manager
InfraStruXure Manager Compatible Customize UPS capabilities with management cards.
LED status indicators Quickly understand unit and power status with visual indicators
Serial connectivity Provides management of the UPS via a serial port.
Adaptability
Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP.
Serviceability
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification Warns when a battery is not available to provide backup power
Audible alarms Provides notification of changing utility power and UPS power conditions
Protection
Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Cold-start capable Provides temporary battery power when the utility power is out.
Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment

Benefits


Default backup time

4 mins

Customer Support: (08) 38.420.458

Head Office

219 Nguyen Dinh Chinh, Ward 11,
Phu Nhuan Dist, Ho Chi Minh City, Vietnam.
Tel: (+84)8.38.420.458 - Fax: (+84).8.38.420.459
Hotline: 0938.805.380 (Mr.Tuấn)

Representative Office

Room 402, 85 Nguyen Chi Thanh,
Dong Da Dist, Hanoi, Vietnam
Tel: (+84)4.35.668.011 - Fax: (+84)4.35.668.030