APC Symmetra LX 12kVA Scalable to 16kVA N+1 Tower

APC Symmetra LX 12kVA Scalable to 16kVA N+1 Tower

Includes:  CD with software, Installation guide, User Manual, Web/SNMP Management Card

Output
Output Power Capacity 9600 Watts / 12 kVA
Max Configurable Power 9600 Watts / 12 kVA
Nominal Output Voltage 120V, 208V
Output Voltage Note Configurable for 120/208 or 120/240 output voltage
Output Voltage Distortion Less than 5% at full load
Other Output Voltages 240
Output Frequency (sync to mains) 47 – 63 Hz
Crest Factor up to 5 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections (1) Hard Wire 4-wire (2PH + N +G)
Bypass Internal Bypass (Automatic and Manual)
Input
Nominal Input Voltage 208V
Input Frequency 45 – 65 Hz (auto sensing)
Input Connections Hard Wire 4-wire (2PH+N+G)
Input voltage range for main operations 96 – 138 (Line to Neutral)V
Other Input Voltages 240V
Input Total Harmonic Distortion Less than 7% for full load
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules 3
Available Battery Module Slots 1
Typical recharge time 3 hour(s)
Extended Run Options APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower
Replacement Battery SYBT5
Communications & Management
Interface Port(s) DB-9 RS-232, SmartSlot
Available SmartSlot™ Interface Quantity 1
Pre-Installed SmartSlot™ Cards AP9631
Control panel Multi-function LCD status and control console
Audible Alarm Audible and visible alarms prioritized by severity
Emergency Power Off (EPO) Yes

раскрутка сайтаprostitute in dubaiклубы бокса в москве

Overview


12r

Features


SYA12K16P Features

 

Removable input/output wiring tray Allows quick and easy installation and maintenance of the UPS.

Benefits


Symmetra Features & Benefits

Availability
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Configurable for N+1 internal redundancy Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Battery modules connected in parallel Delivers higher availability through redundant batteries.
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Scalability
Scalable power capacity Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Scalable runtime Allows additional run time to be quickly added as needed.
Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS
Field-replaceable power distribution panel Ensures compatibility with equipment that has different plug types
Programmable frequency Ensures compatibility with different input frequencies.
Manageability
Network manageable Provides remote power management of the UPS over the network.
SmartSlot Customize UPS capabilities with management cards.
InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.
Manageable external batteries Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime
LCD display Alpha-Numeric Display which displays system parameters and alarms.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging
Serviceability
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced..
Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
User-replaceable intelligence modules Enables simple upgrades and replacements of the Power Modules 
User-replaceable power modules Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
User-replaceable batteries
Disconnected battery notification Warns when a battery is not available to provide backup power.
Protection
Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Cold-start capable Provides temporary battery power when the utility power is out.
Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment

Default backup time

7 mins

Customer Support: (08) 38.420.458