Thank you for visiting!
Our website is being updated.

Liebert APM On-line UPS 120kVA

23Part number: Liebert APM 120 kVA

The most extensive list of optional communication solutions for Liebert APM Systems

—————————————————————————————————-

Specifications:

Output
– Output Power Capacity 120kW/ 120kVA
– Nominal Output Voltage 380/400/415VAC, three-phase four-wire
– Output Frequency  50/60 Hz
– Topology On-line double conversion
– Waveform Type True sinewave
– Output Connections
 Input
 – Nominal Input Voltage  380/400/415VAC, three-phase four-wire
 – Input Frequency  40Hz – 70Hz
– Input Connections
– Input Power Factor > 0.99 at full load, >0.98 at half load
– Bypass Input  voltage 380/400/415VAC, three-phase four-wire
Batteries
– Battery type Battery Cells: Valve-regulated, lead acid batteries
– Battery number 30, 32, 34, 36, 38, 40
– Typical recharge time To 95% capacity within ten (10) times discharge time
– Maximum runtime with internal battery  45-55 mins

 Detail Information:

http://www.emersonnetworkpower.com/en-US/Products/ACPower/LargeFacilityUPS/Pages/LiebertAPMOn-lineUPS15-90kW.aspx

http://www.emersonnetworkpower.com/en-IN/Products/ACPower/LargeFacilityUPS/Documents/New%20APM-Catalogue.pdfрезультаты продвижения сайтовescorts abudhabiкурсы йоги в люблино

Overview


Liebert APM On-line UPS

Features


Efficiency

  • High efficiency rating up to 96% in true online double conversion mode.

Availabilty

  • Lower mean time to repair (MMTR) with hot swappable modules.
  • Distributed intelligence : a system control in each single power module , instead of a centralized one, reduces the failure risk and increases the availability of your infrastructure .
  • High overload protection handles 110% overload for 60 minutes, 125% for 10 minutes, and 150% for 1 minute.

Capacity

  • FlexPower Technology : The unit capacity is easily added, without increasing the system footprint.
  • Liebert APM, accommodates up to 5 x 30 kW power modules per rack and up to 4 UPS racks in parallel.
  • Redundant configuration allows you to substitute one module while the others are working.

Benefits


Flexibility

  • Provides an economical path for growth, with Softscale technology.
  • Allows paralleling of unlike capacities for capacity or redundancy.
  • Offers a large and user-friendly LCD display with operating information in twelve languages.
  • Includes a built-in automatic bypass to transfer the load in case of fault.

Higher Availability

  • True on-line, double conversion technology corrects for all types of power fluctuations.
  • Provides the highest output power quality, with advanced inverter control technology.
  • Provides dual bus synchronization of two UPS units when feeding independent distribution paths.

Lowest Total Cost Of Ownership

  • Optimizes efficiency using soft-switching technology.
  • Extends battery life with temperature-compensated battery charging.
  • DSP control provides highest possible input power factor for maximum efficiency.

Ideally Suited For

  • Small to mid-size data centers
  • Server rooms
  • Production
  • Labs and testing
  • Telecommunications
  • Process control
  • Point of sale

Default backup time

45-55

Customer Support: (08) 38.420.458

Head Office

219 Nguyen Dinh Chinh, Ward 11,
Phu Nhuan Dist, Ho Chi Minh City, Vietnam.
Tel: (+84)8.38.420.458 - Fax: (+84).8.38.420.459
Hotline: 0938.805.380 (Mr.Tuấn)

Representative Office

Room 402, 85 Nguyen Chi Thanh,
Dong Da Dist, Hanoi, Vietnam
Tel: (+84)4.35.668.011 - Fax: (+84)4.35.668.030