MGE Galaxy 5000 120 kVA

Output
Output Power Capacity 108 kW / 120 kVA
Max Configurable Power 108 kW / 120 kVA
Nominal Output Voltage 400V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 92.9%
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Other Output Voltages 300 , 400 , 415
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
Output Voltage Tolerance +/- 1% static and +/- 2 % at 100% load step
Output Voltage THD < 1% linear load and < 2.5% nonlinear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 92.3%
Required Output Current Protection 173A
Neutral Output Current 260 A
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 45 – 65 Hz
Input Connections Hard Wire 4-wire (3PH + G)
Input voltage range for main operations 323 – 437 (380V), 340 – 460 (400V) , 353 – 477 (415)V
Other Input Voltages 380, 400 , 415
,Maximum Input Current 228A
Input Breaker Capacity 315A
Maximum Short Circuit Withstand (Icw) 30.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker
Batteries & Runtime
Battery Type No internal battery – uses external battery system
Communications & Management
Available SmartSlot™ Interface Quantity 3
Control panel Multi-function LCD status and control console
Emergency Power Off (EPO) Optional

 

 

 

 

 topodinescorts southamptonйога для новичков на волжской

Overview


4

Features


 

 

 

 

Top and bottom cable entry (standard) Flexibility that allows the customer to decide - and at no extra cost.
Dual mains input Increases availability by allowing the UPS to be connected to two separate power sources.
Front-access servicing Simplifies installation and UPS maintenance while minimizing space requirements
Locking cabinet Prevents unauthorized access to the UPS.
Parallel-capacity capable Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Parallel-redundant capable Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy

 

Benefits


Availability
Dual mains input Increases availability by allowing the UPS to be connected to two separate power sources.
Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Parallel-capacity capable Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Parallel-redundant capable Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Manageability
Network manageable Provides remote power management of the UPS over the network.
StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
LCD graphics display Text and mimic diagrams that display modes of operation, system parameters and alarms.
LED status indicators Quickly understand unit and power status with visual indicators.
Serviceability
Front-access servicing Simplifies installation and UPS maintenance while minimizing space requirements
Multiple levels of service With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
7x24 telephone technical support Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it
Total Cost of Ownership 
ECO Mode Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Predicitive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Wide input voltage range Designed for harsh electrical environments to save battery life.

 

 

Default backup time


Customer Support: (08) 38.420.458

Head Office

9/35 Pham Van Hai, Ward 1,
Tan Binh District, Ho Chi Minh City, Vietnam.
Tel: (+84)8.38.420.458 - Fax: (+84)8.38.420.459
Hotline: 0938.805.380 (Mr.Tuấn)

Representative Office

B45, Lot 6, Dinh Cong Urban Area, Dinh Cong Ward,
Hoang Mai District, Ha Noi, Vietnam.
Tel: (+84)4.35.668.011 - Fax: (+84)4.35.668.030