Specifications:

Output Ratings
Voltage , Frequency Prime Standby
-/- -/-
480V, 60Hz 225.0kVA/ 180.0 kW 250.0 kVA / 200.0 kW

Ratings at 0.8 power factor.

Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

Standard Reference Conditions

Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Ratings ang Performance Data
Engine Make & Model : Perkins 401306A – E87TAG4
Alter manufactured for FG Wilson by : Marelli
Alternator model : MJB 250LA4
Control Panel : PowerWizard 1.1+
Base Frame : Heavy Duty Fabricated steel
Circuit Breaker Type : 3 Pole MCB
Frequency : 50 Hz 60 Hz
Engine Speed : RPM 1800
Fuel Tank Capacity :

Litres (US gal)

464 (122.6)
Fuel Consumption : l/hr (US gal/hr)

(100% Load)                                 – Prime

–         Standby

52.5 (13.9)

55.8 (14.7)

Available Options
FG Wilson ofer a range of optional features to tailor our generating sets to meet your power needs . Options include:

·        Upgrade to CE Certification

·        A wide range of Sound Attenuated Enclosures

·        A variety og generating set control panels

·        Additional alarms and shutdowns

For futher information on all of the standard and optional features accompanying this product please contact your local Dealer or visit : www.FGWilson.com

Dimensions and weights
Length (L)

mm (in)

With (W)

mm (in)

Height (H)

mm (in)

Dry

Kg (Ib)

Wet

Kg (Ib)

2662 (104.8) 1030 (40.6) 1760 (69.3) 1902 (4193) 1924 (4242)
Dry = With Lube Oil                     Wet = With Lube Oil and Coolant
Engine Technial Data
No. of Cylinders / Alignment 6 / In Line
Cycle 4 Stroke
Bore / Stroke : mm (in) 116.6 (4.6) / 135.9 (5.4)
Induction : Turbocharged Air To Air Charge Cooled
Cooling Method: Water
Governing Type Electronic
Governing Class ISO 8528 G2
Compression Ratio : 16.9:1
Displacement :I (cu.  in) 8.7 (530.9)
Moment of Inertia: kg m2 (Ib/in2) 1.54 (5266)
Engine Electrical System:

-Voltage / Ground

-Battery Charger Amps

24/Negative
50
Weight : kg(Ib)            – Dry

-Wet

671 (1479)

698 (1539)

Performance 50 Hz 60 Hz
Engine Speed : rpm 1800
Gross Engine Power : kW (hp)

-Prime

-Standardby

233.0 (312.0)

255.0 (342.0)

BMEP : kPa (psi)

-Prime

-Standardby

1784.0 (258.8)

1953.0 (283.2)

Fuel System
Fuel Filter Type Replaceable Element
Recommended Fuel : Class A2 Diesel or BSEN590
Fuel Consumption : l/hr (US gal/hr)
 

Prime

110%

Load

100%

Load

75%

Load

50%

Load

50 Hz
60 Hz 55.8 (14.7) 52.5 (13.9) 43.8 (11.6) 33.7 (8.9)
 

Standby

100%

Load

75%

Load

50%

Load

50 Hz
60 Hz 55.8 (14.7) 46.7 (12.3) 36.0 (9.5)
Air Systems 50 Hz 60 Hz
Air Filter Type : Paper Element
Combustion Air Flow : m3/min (cfm)

-Prime

-Standardby

19.8 (699)

20.4 (720)

Max. Combustion Air Intake

Restriction : kPa (in H2O)

6.2 (25.0)
Cooling System 50 Hz 60 Hz
Cooling System Capacity : I (US gal) 24.7 (6.5)
Water Pump Type : Centrifugal
Heat Rejected to Water & Lube Oil :

 kW (Btu/ min)                                 -Prime

-Standardby

103.0 (5858)

106.0 (6028)

Heat Radiation to Rom : Heat radiated from engine and altemator

kW (Btu/ min)                                 -Prime

-Standardby

21.3 (1211)

24.6 (1399)

Radiator Fan Load : kW (hp) 16.9 (22.7)
(Radiator Cooling Airflow : m3/min (cfm) 435.6 (15383)
External Restriction to

Cooling Airflow : Pa (in H2O)

125 (0.5)
Lubrication System
Oil Filter Type : Spin – On , Full Flow
Total Oil Capacity : I (US gal) 26.5 (7.0)
Oil Pan : I (US gal) 22.7 (6.0)
Oil Type : API CI – 4
Oil Cooling Method: Water
Exhaust System 50 Hz 60 Hz
Maximum Allowable Back Pressure : kPa (in Hg) 10.7 (3.2)
Exhaust Gas Flow : m3/min (cfm)

-Prime

-Standardby

46.5 (1642)

51.3 (1812)

Exhaust Gas Temperature : oC( oF)

-Prime

-Standardby

447 (837)

497 (927)

Alternator Physical Data
Manufactured for FG Wilson by: Marelli
Model : MJB 250LA4
No . of Bearings : 1
Insulation Class : H
Winding Pitch Code 2/3 – M0
Wires : 12
Ingress protection Rating : IP23
Eccitation System : SHUNT
AVR Model : Mark V
Alternator Operating Data
Overspeed : rpm 2250
Voltage Reguation : (steady state) + / – 0.5%
Wave Form NEMA = TIF 50
Wave Form IEC = THF 2.0%
Total Harmonic content LL/LN 2.0%
Radio Interference : Suppression is in line with European

Standard EN55011

Radiant Heat : kW (Btu/min)

-50Hz

– 60Hz

14.6 (830)

Alternator

Performance Data

50 Hz 60 Hz
Data Item 480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

440/254V

220/127V

Motor Starting

Capability*kVA

280 212 240 260
Short Circuit

Capacity %

300 300 300 300
Reactances : Per Unit

Xd

X’d

X”d

2.898

0.244

0.095

3.477

0.389

0.152

3.858

0.325

0.127

3.449

0.290

0.114

Output Ratings Technical Data 50Hz
Voltage Prime: Standby:
kVA kW kVA kW
Output Ratings Technical Data 60Hz
Voltage Prime: Standby:
kVA kW kVA kW
480/277V 225.0 180.0 250.0 200.0
200/127V 225.0 180.0 250.0 200.0
380/220V 225.0 180.0 250.0 200.0
240/120V 225.0 180.0 250.0 200.0
440/254V 225.0 180.0 250.0 200.0
220/110V 225.0 180.0 250.0 200.0
208/120V 225.0 180.0 250.0 200.0
240/139V 225.0 180.0 250.0 200.0

F330H – 1 (330kVA)

Specifications:

Output Ratings
Voltage , Frequency Prime Standby
400V , 50 Hz 300.0 kVA / 240.0 kW 330.0 kVA / 264.0 kW
-/- -/-

Ratings at 0.8  power factor.

Please refer to the output ratings technical data section for specific generator set outputs per voltage.

Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

Standard Reference Conditions

Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Ratings ang Performance Data
Engine Make & Model : Perkins 1606A –E93TAG5
Alter manufactured for FG Wilson by : Leroy Somer
Alternator model : LL5014L
Control Panel : PowerWizard 1.1 +
Base Frame : Heavy Duty Fabricated steel
Circuit Breaker Type : 3 Pole MCCB
Frequency : 50 Hz 60 Hz
Engine Speed : RPM 1500
Fuel Tank Capacity :Litres (US gal) 617 (163.0)
Fuel Consumption : l/hr (US gal/hr) (100% Load)                                 – Prime–         Standby 59.5 (15.7)64.8 (17.1)
Available Options
FG Wilson ofer a range of optional features to tailor our generating sets to meet your power needs . Options include:·        Upgrade to CE Certification·        A wide range of Sound Attenuated Enclosures

·        A variety og generating set control panels

·        Additional alarms and shutdowns

For futher information on all of the standard and optional features accompanying this product please contact your local Dealer or visit : www.FGWilson.com

Dimensions and weights
Length (L)mm (in) With (W)mm (in) Height (H)mm (in) DryKg (Ib) WetKg (Ib)
3300 (129.9) 1100 (43.3) 4848 (72.8) 2724 (6005) 2755 (6074)
Dry = With Lube Oil                     Wet = With Lube Oil and Coolant
Engine Technial Data
No. of Cylinders / Alignment 6 / In Line
Cycle 4 Stroke
Bore / Stroke : mm (in) 116.6 (4.6)/ 146.0 (5.7)
Induction : Turbocharged Air To Air Charge Cooled
Cooling Method: Water
Governing Type Electronic
Governing Class ISO 8528 G2
Compression Ratio : 17.2 : 1
Displacement :I (cu.  in) 9.3 (567.5)
Moment of Inertia: kg m2 (Ib/in2) 1.95 (66547)
Engine Electrical System:-Voltage / Ground-Battery Charger Amps 24/Negative
70
Weight : kg(Ib)            – Dry-Wet 827 (1823)860 (1896)
Performance 50 Hz 60 Hz
Engine Speed : rpm 1500
Gross Engine Power : kW (hp)-Prime-Standardby 271.0 (363.0)297.0 (398.0)
BMEP : kPa (psi)-Prime-Standardby 2318.0 (336.2)2540.0 (368.4)
Fuel System
Fuel Filter Type Replaceable Element
Recommended Fuel : Class A1/A2 Diesel or BSEN590
Fuel Consumption : l/hr (US gal/hr)
 Prime 110%Load 100%Load 75%Load 50%Load
50 Hz 64.8 (17.1) 59.5 (15.7) 46.2 (12.2) 33.3 (8.8)
60 Hz
 Standby 100%Load 75%Load 50%Load
50 Hz 64.8 (17.1) 50.2 (13.3) 35.8 (9.5)
60 Hz
Air Systems 50 Hz 60 Hz
Air Filter Type : Paper Element
Combustion Air Flow : m3/min (cfm)-Prime-Standardby 18.3 (648)19.7 (696)
Max. Combustion Air IntakeRestriction : kPa (in H2O) 4.0 (16.1)
Cooling System 50 Hz 60 Hz
Cooling System Capacity : I (US gal) 30.9 (8.2)
Water Pump Type : Centrifugal
Heat Rejected to Water & Lube Oil : kW (Btu/ min)                                 -Prime-Standardby 123.0 (6995)132.0 (7507)
Heat Radiation to Rom : Heat radiated from engine and altematorkW (Btu/ min)                                 -Prime-Standardby 27.6 (1570)

29.8 (1695)

Radiator Fan Load : kW (hp) 10.0 (13.45)
Radiator Cooling Airflow : m3/min (cfm) 609.0 (21507)
External Restriction toCooling Airflow : Pa (in H2O) 125 (0.5)
Lubrication System
Oil Filter Type : Spin – On , Full Flow
Total Oil Capacity : I (US gal) 36.0 (9.5)
Oil Pan : I (US gal) 33.0 (8.7)
Oil Type : API CI – 4
Oil Cooling Method: Water
Exhaust System 50 Hz 60 Hz
Maximum Allowable Back Pressure : kPa (in Hg) 10.0 (3.0)
Exhaust Gas Flow : m3/min (cfm)-Prime-Standardby 44.1 (1558)47.6 (1681)
Exhaust Gas Temperature : oC( oF)-Prime-Standardby 373 (703)410 (770)
Alternator Physical Data
Manufactured for FG Wilson by: Leroy Somer
Model : LL5014L
No . of Bearings : 1
Insulation Class : H
Winding Pitch Code 2/3 – 6
Wires : I2
Ingress protection Rating : IP23
Eccitation System : SHUNT
AVR Model : R250
Alternator Operating Data
Overspeed : rpm 2250
Voltage Reguation : (steady state) + / – 0.5%
Wave Form NEMA = TIF 100
Wave Form IEC = THF 2.0%
Total Harmonic content LL/LN 4.0%
Radio Interference : Suppression is in line with EuropeanStandard EN61000 – 6
Radiant Heat : kW (Btu/min)-50Hz– 60Hz 17.8 (1012)-
AlternatorPerformance Data 50 Hz 60 Hz
Data Item 415/240V 400/230V 380/220V
Motor StartingCapability*kVA 793 745 682
Short CircuitCapacity %
Reactances : Per UnitXdX’d

X”d

2.4060.107

0.064

2.5890.116

0.069

2.8690.128

0.076

Output Ratings Technical Data 50Hz
Voltage Prime: Standby:
kVA kW kVA kW
415/240V 300.0 240.0 330.0 264.0
400/230V 300.0 240.0 330.0 264.0
380/220V 300.0 240.0 330.0 264.0
Output Ratings Technical Data 60Hz
Voltage Prime: Standby:
kVA kW kVA kW

Detail Information:

https://www.fgwilson.com/cda/files/4665194/7/P249H-3%20GB.pdf

https://www.fgwilson.com/cda/files/4261316/7/275-330%20kVA%20SA%20Enclosure(GB)(1112).pdf

topod.indubai tantra massageрукопашный бой братиславская

Overview


200-330kVA

Features


Benefits


Default backup time

Customer Support: (08) 38.420.458

Head Office

9/35 Pham Van Hai, Ward 1,
Tan Binh District, Ho Chi Minh City, Vietnam.
Tel: (+84)8.38.420.458 - Fax: (+84)8.38.420.459
Hotline: 0938.805.380 (Mr.Tuấn)

Representative Office

B45, Lot 6, Dinh Cong Urban Area, Dinh Cong Ward,
Hoang Mai District, Ha Noi, Vietnam.
Tel: (+84)4.35.668.011 - Fax: (+84)4.35.668.030