Thank you for visiting!
Our website is being updated.

Smart-UPS On-Line RT 5000VA 230V

Part number: SURTD5000XLI

Compact UPS Systems for High Power Network Rack Applications

Includes:

The internal battery  packs are hot-swappable, and user replaceable. The unit also supports up to four external battery cabinets for extended run time.

————————————————————————————————-

Specifications:

Output
– Output Power Capacity 3500W/5000VA
Max Configurable Power 3500W/5000VA
– Nominal Output Voltage 230 V
Output Voltage  Note Configurable for 220 : 230 or 240 nominal output voltage
Efficiency at full load 92.0%
Output Voltage  Distortion Less than 3%
– Output Frequency  50/60 Hz +/-3Hz user adjustable +/- 0.1
Other output Voltage 220 , 240V
– Topology Double conversion online
– Waveform Type Sine wave
– Output Connections (8) IEC 320 C13 , (2) IEC 320 C19 , (2) IEC jumpers
Bypass Intermal Bypass ( automatic and manual )
 Input
 – Nominal Input Voltage  230V
 – Input Frequency  50/60 Hz +/-5Hz (auto sensing )
– Input Connections  Hard Wire 3-wire
Cord Length 2.44 meters
Input Voltage  range for main operations 160 – 280V
Other Input Voltage 220 , 240V
Batteries & Runtime
– Battery type Maintenace-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Inc luded Battery Modules 2
– Typical recharge time 2.5 hour(s)
– Replacement Battery RBC144
RBCTM  Quantily 1
Extended Run options APC Smart-UPS RT 3000VA 230V

http://www.apc.com/products/runtimegraph/runtime_graph.cfm?base_sku=surtd5000xli&chartSize=large

Communication & Management
Interface Port(s) RJ-45 10/100 Base- T, RJ-45 Serial, Smart-Slot
Pre Intallel , SmartSlotTM Cards AP9631
Control panel LED status display with load and battery bar-graphs and online: on battery: Replace Battery : Overload and and bypass indicators
Audible Alarm Alarm when on battery : distinctive  low battery alarm : Overload  continuous tone alarm
Emergency Power Off (EPO) Yes
Surge Protection and Filtering
Surge energy rating 555J Joules
Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449

продвижениеelite escortsрадиаторы отопления узкие горизонтальные

Overview


surtd5k-xli

Features


Availability

Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtime Allows additional run time to be quickly added as needed.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature
Manageability
Network manageable Provides remote power management of the UPS over the network.
InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.
SmartSlot Customize UPS capabilities with management cards.
LED status indicators Quickly understand unit and power status with visual indicators.
Serial connectivity Provides management of the UPS via a serial port.
Adaptability
Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP.
Serviceability
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predicitive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification Warns when a battery is not available to provide backup power.
Audible alarms Provides notification of changing utility power and UPS power conditions
Protection
Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Cold-start capable Provides temporary battery power when the utility power is out.
Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Benefits


Default backup time

6 mins

Customer Support: (08) 38.420.458

Head Office

219 Nguyen Dinh Chinh, Ward 11,
Phu Nhuan Dist, Ho Chi Minh City, Vietnam.
Tel: (+84)8.38.420.458 - Fax: (+84).8.38.420.459
Hotline: 0938.805.380 (Mr.Tuấn)

Representative Office

Room 402, 85 Nguyen Chi Thanh,
Dong Da Dist, Hanoi, Vietnam
Tel: (+84)4.35.668.011 - Fax: (+84)4.35.668.030